تخطَّ إلى المحتوى
Download.sa داونلود السعودية
ثبّت داونلود السعودية على آيفون أو آيباد: اضغط زر المشاركة ثم اختر «إضافة إلى الشاشة الرئيسية».

سجل إصدارات ⁨Homematic-Manager⁩

كل الإصدارات المتابعة من المصدر الرسمي مع سجل التغييرات والملفات.

إصدارات 2026

  1. 3.8.0

    الأحدث عبر GitHub Releases صدر في
    سجل التغييرات
    ## 3.8.0 — 2026-11-22 Thanks to @agross for testing the calibration on his device in #172. ### Added - **The end positions of an HmIP tubular motor can be calibrated by hand.** The values of the shutter channel of a motor that has this calibration (the HmIP-M-TD15 and its twin RM-110-45/15) show whether the end positions are saved, and _Calibrate…_ opens the steps of the CCU's WebUI "Calibration of the end positions": move the shutter up or down by 100 ms, 400 ms or a number of seconds, change the motor's direction, save the upper and then the lower end position, or delete them. The dialog warns that the motor moves, its STOP is always there, and closing it stops a motor it set moving. Built from the WebUI's code and tested against a device description derived from it only, not on a real motor: feedback from a real one is welcome. - `paramset.put` takes a `command` option for the VALUES of one channel: the given datapoints go out together in one `putParamset`, without reading first and without dropping a value as unchanged. ### Fixed - **The running times measured by the automatic calibration show in the open settings.** The device reports the end of the run a few seconds before the system has its measured times, so the dialog said they were read but kept the old ones until it was opened again. It now reads them again until they arrive, for up to a minute, and says so while it waits; the new times count as the device's values, not as changes to write. (#172, @agross) - **The running times of the calibration block have readable labels.** An HmIP blind channel showed the raw parameter name, cut off, over the same raw name; the rows now carry the CCU's labels ("Running time top to bottom", "Fahrzeit von oben nach unten" and so on) with the raw name below. A label longer than its column wraps instead of being cut off, a parameter without a label shows its raw name once, and on a phone the calibration and duration rows put the label above the input. (#172, @agross) **Full Changelog**: https://github.com/hobbyquaker/homematic-manager/compare/v3.7.1...v3.8.0

ثبّت داونلود على جهازك

افتحه من شاشتك الرئيسية بنقرة واحدة، في نافذة خاصة به.

ثبّت داونلود السعودية على آيفون أو آيباد: اضغط زر المشاركة ثم اختر «إضافة إلى الشاشة الرئيسية».